iVS ACTUATOR

iVS range electric actuators are designed for quarter-turn operating applications requiring a fail position upon loss of power supply. They utilize a compact mechanical spring set to fail the valve or damper clockwise (CLOSE) or counter-clockwise (OPEN).

KEY FEATURES
  • Output torques ranging from 50 N•m (440 lb•in) to 260 N•m (2,300 lb•in)
  • Enclosures meeting the sealing standards of CSA and NEMA Type 4X along with IP67 Ingress Protection
  • Optional Clutch-less Geared Manual Handwheel Override
  • TWO POSITION, ON/OFF or Modulating Control

Output torques ranging from 50 N•m (440 lb•in) to 260 N•m (2,300 lb•in)
High grade aluminum enclosures, which are hard anodized both inside and out
Exterior protected with a durable polyester powder coating
Covers utilizing O-ring sealing and captive stainless-steel fasteners
Enclosures meeting the sealing standards of CSA and NEMA Type 4X along with IP67 Ingress Protection
Visual Position Indicator as standard
Adjustable mechanical buffer for the fail end position as standard
Mounting base conforming to ISO 5211 as standard
Space heater and thermostat provided as standard
Standard Operating Temperature range of -30°C to +65°C (-22°F to +149°F)
Standard voltages of 24V DC, 24V AC, 110V/220V AC, 1PH, 60Hz ±10%
TWO POSITION Control as standard
Standard 50% Duty Cycle at 30% rated torque
Ratings from 30 to 60 starts/movements per hour for inching control with a cyclic duration factor of not less than 25%
Built-in Resettable Motor Thermal Protection
Standard 4 limit switches: 2 for operation, 2 x SPDT for extra dry contacts

 

Available Options:
Explosionproof Enclosures for Hazardous environments (CSA and NEMA Type 7 for Class I Div 1 Groups C&D areas and CSA and NEMA 9 for Class II Div 1 Groups E, F & G areas)
ON/OFF Control (3-Position)
Modulating Control
4-20mA Current Position Transmitter or Potentiometer (1K or 5K)
Clutch-less Geared Manual Handwheel Override
IP68 Ingress Protection provided as standard with Explosionproof Enclosures

Output Torque (N•m)Output Torque (lb•in)EnclosureFail DirectioniVact Model DrawingiVact 3D STP Model
50445WatertightClockwiseIVS-ANWN-XIV-2024
50445WatertightClockwiseIVS-AHWN-XIV-2025
1301,150WatertightClockwiseIVS-BNWN-XIV-2026
1301,150WatertightClockwiseIVS-BHWN-XIV-2027
2001,770WatertightClockwiseIVS-CNWN-XIV-2028
2001,770WatertightClockwiseIVS-CHWN-XIV-2029
2602,300WatertightClockwiseIVS-DNWN-XIV-2030
2602,300WatertightClockwiseIVS-DHWN-XIV-2031
50445WatertightCounter-ClockwiseIVS-ANWN-YIV-2032
50445WatertightCounter-ClockwiseIVS-AHWN-YIV-2033
1301,150WatertightCounter-ClockwiseIVS-BNWN-YIV-2034
1301,150WatertightCounter-ClockwiseIVS-BHWN-YIV-2035
2001,770WatertightCounter-ClockwiseIVS-CNWN-YIV-2036
2001,770WatertightCounter-ClockwiseIVS-CHWN-YIV-2037
2602,300WatertightCounter-ClockwiseIVS-DNWN-YIV-2038
2602,300WatertightCounter-ClockwiseIVS-DHWN-YIV-2039
50445ExplosionproofClockwiseIVS-ANEN-XIV-2051
50445ExplosionproofClockwiseIVS-AHEN-XIV-2052
1301,150ExplosionproofClockwiseIVS-BNEN-XIV-2053
1301,150ExplosionproofClockwiseIVS-BHEN-XIV-2054
2001,770ExplosionproofClockwiseIVS-CNEN-XIV-2055
2001,770ExplosionproofClockwiseIVS-CHEN-XIV-2056
2602,300ExplosionproofClockwiseIVS-DNEN-XIV-2057
2602,300ExplosionproofClockwiseIVS-DHEN-XIV-2058
50445ExplosionproofCounter-ClockwiseIVS-ANEN-YIV-2059
50445ExplosionproofCounter-ClockwiseIVS-AHEN-YIV-2060
1301,150ExplosionproofCounter-ClockwiseIVS-BNEN-YIV-2061
1301,150ExplosionproofCounter-ClockwiseIVS-BHEN-YIV-2062
2001,770ExplosionproofCounter-ClockwiseIVS-CNEN-YIV-2063
2001,770ExplosionproofCounter-ClockwiseIVS-CHEN-YIV-2064
2602,300ExplosionproofCounter-ClockwiseIVS-DNEN-YIV-2065
2602,300ExplosionproofCounter-ClockwiseIVS-DHEN-YIV-2066

iVS Range Wiring Diagram Codes and DescriptionsiVS Range ModelsiVS Range Wiring Diagram Numbers
SA - 24V AC/DC TWO POSITION with Heater, Thermostat and Auxiliary Switches 50% DutyiVS-A,B,C,D
iVS-A,B,C,D
S-1AN21NNN-1
S-1AN21NNN-2
SB - 110/220V AC TWO POSITION with Heater, Thermostat and Auxiliary Switches 50% DutyiVS-A
iVS-B,C,D
S-2AN21NNN-1
S-2AN21NNN-2
SC - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 50% DutyiVS-A
iVS-B,C,D
S-2BN21N3N-1
S-2BN21N3N-2
SD - 110/220V AC ON/OFF with Heater, Thermostat and Auxiliary Switches 50% DutyiVS-A
iVS-B,C,D
S-2BN21NNN-1
S-2BN21NNN-2
SE - 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 50% DutyiVS-A
iVS-B,C,D
S-2CN21N3N-1
S-2CN21N3N-2