iVQ ACTUATOR

iVQ Range electric actuators are designed for quarter-turn operating applications on valves and dampers.

KEY FEATURES
  • Output torques ranging from 6 N•m (53 lb•in) to 3,500 N•m (31,000 lb•in)
  • Enclosures meeting the sealing standards of CSA and NEMA Type 4X along with IP67 Ingress Protection
  • Manual Override as standard
  • ON/OFF or Modulating Control

Output torques ranging from 6 N•m (53 lb•in) to 3,500 N•m (31,000 lb•in)
Compact designs which are robust and rugged
High grade aluminum alloy enclosures
Exteriors protected with a durable polyester powder coating
Covers utilizing O-ring sealing and captive stainless-steel fasteners
Enclosures meeting the sealing standards of CSA and NEMA Type 4X along with IP67 Ingress Protection
Self locking EPI-CYCLICAL gear train with minimum backlash, which provides for a smooth running and dependable drive system
Grease lubricated drive train for life
Manual Override as standard
Handwheel for manual operation, which has a non-clutch design and requires no manual/auto lever (except on iVQ-A, B, C, D which use a lever)
Visual Position Indicator as standard (except on iVQ-A, B)
Mechanical stop bolts as standard (except on iVQ-A, B, C, D)
Mounting base conforming to ISO 5211 standard
Space heater and thermostat as standard (except on iVQ-A, B)
Standard Operating Temperature range of -30°C to +65°C (-22°F to +149°F)
Standard voltages of 24V DC, 24V AC, 110V/220V AC, 1PH, 60Hz ±10%
ON/OFF Control as standard
Standard 30% Duty Cycle at 30% rated torque
Ratings from 30 to 120 starts/movements per hour for inching control with a cyclic duration factor of not less than 25%
Built-in Resettable Motor Thermal Protection

Available Options:
Explosionproof Enclosures for Hazardous Environments (CSA and NEMA Type 7 for Class I Div 1 Groups C & D areas and CSA and NEMA 9 for Class II Div 1 Groups E, F & G areas) (Available for iVQ-C, D, F, H, J, K, L, M & N)
IP68 Ingress Protection provided as standard with Explosionproof Enclosures
Modulating Control with ratings from 300 to 1200 starts/movements per hour
50% and 75% Duty Cycle at 30% rated torque for ON/OFF and Modulating Control
Local Controls with Watertight Enclosures
Torque Switches
4-20mA Current Position Transmitter or Potentiometer (1K or 5K)
Interrupter Timer (slows down the running time)
Chainwheel (c/w 5m of chain)
316 Stainless Steel Enclosures
Junction Box
Extended Travel
Class H motor insulation

Output Torque (N•m) Output Torque (lb•in) Enclosure iVact Model Drawing
6 55 Watertight iVQ-ALWN (DC models)
6 55 Watertight iVQ-ALWN (AC models)
15 130 Watertight iVQ-BLWN (DC models)
15 130 Watertight iVQ-BLWN (AC models)
35 310 Watertight iVQ-CLWN
50 445 Watertight iVQ-DNWN
50 445 Watertight iVQ-DLWN
65 575 Watertight iVQ-EHWN
90 800 Watertight iVQ-FHWN
120 1,065 Watertight iVQ-GHWN
150 1,330 Watertight iVQ-HHWN
300 2,665 Watertight iVQ-IHWN
400 3,540 Watertight iVQ-JHWN
500 4,430 Watertight iVQ-KHWN
650 5,755 Watertight iVQ-LHWN
1,000 8,855 Watertight iVQ-MHWN
1,500 13,280 Watertight iVQ-NHWN
2,000 17,710 Watertight iVQ-OHWN
2,500 22,140 Watertight iVQ-PHWN
3,000 26,565 Watertight iVQ-QHWN
3,500 31,000 Watertight iVQ-RHWN
35 310 Explosionproof IVQ-CLEN
50 445 Explosionproof IVQ-DNEN
50 445 Explosionproof IVQ-DLEN
90 800 Explosionproof IVQ-FHEN
150 1,330 Explosionproof IVQ-HHEN
400 3,540 Explosionproof IVQ-JHEN
500 4,430 Explosionproof IVQ-KHEN
650 5,755 Explosionproof IVQ-LHEN
1,000 8,855 Explosionproof IVQ-MHEN
1,500 13,280 Explosionproof IVQ-NHEN
35 310 Watertight w/Local Control Unit iVQ-CLWL
50 445 Watertight w/Local Control Unit iVQ-DNWL
50 445 Watertight w/Local Control Unit iVQ-DLWL
65 575 Watertight w/Local Control Unit iVQ-EHWL
90 800 Watertight w/Local Control Unit iVQ-FHWL
120 1,065 Watertight w/Local Control Unit iVQ-GHWL
150 1,330 Watertight w/Local Control Unit iVQ-HHWL
400 3,540 Watertight w/Local Control Unit iVQ-JHWL
500 4,430 Watertight w/Local Control Unit iVQ-KHWL
650 5,755 Watertight w/Local Control Unit iVQ-LHWL
1,000 8,855 Watertight w/Local Control Unit iVQ-MHWL
1,500 13,280 Watertight w/Local Control Unit iVQ-NHWL
2,000 17,710 Watertight w/Local Control Unit iVQ-OHWL
2,500 22,140 Watertight w/Local Control Unit iVQ-PHWL
3,000 26,565 Watertight w/Local Control Unit iVQ-QHWL
3,500 31,000 Watertight w/Local Control Unit iVQ-RHWL
iVQ Range Wiring Diagram Codes and Descriptions iVQ Range Models iVQ Range Wiring Diagram Numbers
QA - 24V DC ON/OFF 30% Duty iVQ-A, B Q-1ANNNNNN-1
QB - 24V AC/DC ON/OFF with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 50% Duty iVQ-O to R
iVQ-O to R
Q-1CL21N3N-1
Q-1CL21N3N-2
QC - 24V AC/DC ON/OFF with Heater, Thermostat, Auxiliary Switches and Local Control Unit 50% Duty iVQ-O to R
iVQ-O to R
Q-1CL21NNN-1
Q-1CL21NNN-2
QD - 24V AC/DC ON/OFF with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 50% Duty iVQ-O to R
iVQ-O to R
Q-1CN21N3N-1
Q-1CN21N3N-2
QE - 24V AC/DC ON/OFF with Heater, Thermostat and Auxiliary Switches 50% Duty iVQ-O to R
iVQ-O to R
Q-1CN21NNN-1
Q-1CN21NNN-2
QF - 24V AC/DC Modulating with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 50% Duty iVQ-O to R
iVQ-O to R
Q-1DL21N3N-1
Q-1DL21N3N-2
QG - 24V AC/DC Modulating with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 50% Duty iVQ-O to R
iVQ-O to R
Q-1DN21N3N-1
Q-1DN21N3N-2
QH - 24V AC/DC ON/OFF with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 75% Duty iVQ-C, D
iVQ-E to L
iVQ-M, N
iVQ-M, N
Q-1EL21N3N-1
Q-1EL21N3N-2
Q-1EL21N3N-3
Q-1EL21N3N-4
QI - 24V AC/DC ON/OFF with Heater, Thermostat, Auxiliary Switches and Local Control Unit 75% Duty iVQ-C, D
iVQ-E to L
iVQ-M, N
iVQ-M, N
Q-1EL21NNN-1
Q-1EL21NNN-2
Q-1EL21NNN-3
Q-1EL21NNN-4
QJ - 24V AC/DC ON/OFF with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 75% Duty iVQ-C, D
IVQ-E to L
iVQ-M, N
iVQ-M, N
Q-1EN21N3N-1
Q-1EN21N3N-2
Q-1EN21N3N-3
Q-1EN21N3N-4
QK - 24V AC/DC ON/OFF with Heater, Thermostat and Auxiliary Switches 75% Duty iVQ-C, D
IVQ-E to L
iVQ-M, N
iVQ-M, N
Q-1EN21NNN-1
Q-1EN21NNN-2
Q-1EN21NNN-3
Q-1EN21NNN-4
QL - 24V AC/DC Modulating with Heater, Thermostat, Auxiliary Switches, 4-20mA
Feedback and Local Control Unit 75% Duty
iVQ-E to L
iVQ-M, N
iVQ-M, N
Q-1FL21N3N-1
Q-1FL21N3N-2
Q-1FL21N3N-3
QM - 24V AC/DC Modulating with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 75% Duty iVQ-C,D
iVQ-E to L
iVQ-M, N
iVQ-M, N
Q-1FN21N3N-1
Q-1FN21N3N-2
Q-1FN21N3N-3
Q-1FN21N3N-4
QN - 110/220V AC ON/OFF 30% Duty iVQ-A, B Q-2ANNNNNN-1
QO - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 30% Duty iVQ-C,D
iVQ-E to R
Q-2AL21N3N-1
Q-2AL21N3N-2
QP - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and Local Control Unit 30% Duty iVQ-C, D
iVQ-E to R
Q-2AL21NNN-1
Q-2AL21NNN-2
QQ - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 30% Duty iVQ-C,D
iVQ-E to R
Q-2AN21N3N-1
Q-2AN21N3N-2
QR - 110/220V AC ON/OFF with Heater, Thermostat and Auxiliary Switches 30% Duty iVQ-C, D
iVQ-E to R
Q-2AN21NNN-1
Q-2AN21NNN-2
QS - 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 30% Duty iVQ-E to N Q-2BL21N3N-1
QT - 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 30% Duty iVQ-E to N Q-2BN21N3N-1
QU - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 50% Duty iVQ-O to R
iVQ-O to R
Q-2CL21N3N-1
Q-2CL21N3N-2
QV - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and Local Control Unit 50% Duty iVQ-O to R
iVQ-O to R
Q-2CL21NNN-1
Q-2CL21NNN-2
QW - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 50% Duty iVQ-O to R
IVQ-O to R
Q-2CN21N3N-1
Q-2CN21N3N-2
QX - 110/220V AC ON/OFF with Heater, Thermostat and Auxiliary Switches 50% Duty iVQ-O to R
iVQ-O to R
Q-2CN21NNN-1
Q-2CN21NNN-2
QY - 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 50% Duty iVQ-O to R
iVQ-O to R
Q-2DL21N3N-1
Q-2DL21N3N-2
QZ - 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 50% Duty iVQ-O to R
iVQ-O to R
Q-2DN21N3N-1
Q-2DN21N3N-2
RA - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 75% Duty iVQ-E to N Q-2EL21N3N-1
RB - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and Local Control Unit 75% Duty iVQ-C,D
iVQ-E to N
Q-2EL21NNN-1
Q-2EL21NNN-2
RC - 110/220V AC ON/OFF with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 75% Duty iVQ-C,D
iVQ-E to N
Q-2EN21N3N-1
Q-2EN21N3N-2
RD - 110/220V AC ON/OFF with Heater, Thermostat and Auxiliary Switches 75% Duty iVQ-C,D
iVQ-E to N
Q-2EN21NNN-1
Q-2EN21NNN-2
RE – 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches, 4-20mA Feedback and Local Control Unit 75% Duty iVQ-E to N Q-2FL21N3N-1
RF - 110/220V AC Modulating with Heater, Thermostat, Auxiliary Switches and 4-20mA Feedback 75% Duty iVQ-C,D
iVQ-E to N
Q-2FN21N3N-1
Q-2FN21N3N-2